Product Features

Patented Sensor Technology
The instrument uses Labthink™s proprietary electrolytic sensor for water vapor analysis, which has excellent precision, repeatability and service life. As a coulometric electrolytic sensor, its signal follows the Faraday principle and has a very high sensitivity.

New Generation Integrated Testing Block
The patented three-cell integrated test block structure using advanced thermodynamics and hydrodynamics analysis greatly improves the temperature, humidity and flow measurement accuracy across the three test cells and supports simultaneous testing of three samples.

Automatic Control of Temperature and Humidity
The internal temperature and humidity of the instrument are automatically adjusted with temperature and humidity sensors, maintaining the stability of the test specimen environment.

Easy-to-use and High-efficiency System
The automatic test mode, combined with the instrument features, eliminates the need for manual adjustments to quickly obtain accurate results, saving training costs and releasing staff from manual monitoring so that they are available for other tasks.
The professional test mode provides flexible and rich instrument control functions to meet individual scientific research needs.
Unique, optional DataShieldTM system, meets the requirements for centralized management of user data. It supports a variety of formats of exported data. Reliable security algorithms are used to prevent data leakage. It supports universal wired and wireless LAN, optional private wireless network and third-party software.

User-oriented Service Concept
Adhering to our user-oriented service concept, Labthink has created a customization system that provides flexible and comprehensive customization services for the accommodation of non-standard specimens and packages.

Test Principle

The test specimen is mounted in the diffusion cell, which is divided into a dry chamber and a controlled-humidity chamber. The dry side of the specimen is swept by a flow of dry nitrogen, and the water vapor permeating through the specimen from the controlled-humidity chamber is carried by dry nitrogen to the electrolytic sensor where proportion electrical signals will be generated. The water vapor transmission rate is obtained by analyzing and calculating the electrical signals. For whole package specimen, the dry nitrogen flows inside the specimen while the outside of specimen is maintained in a high humidity environment.

Test Standards

ISO 15106-3, ASTM F3299, GB/T 21529, YBB 00092003-2015

Applications

Basic Applications
  • Films
    Plastic films, paper-plastic composite films, coextruded films, aluminum foils, aluminum composite films, glass fiber aluminum foil composite films and many others.
  • Sheeting
    PP, PVC and PVDC sheets, metal foils, rubber pads, silicon wafers and other sheeting materials.
  • Packages
    Plastic, rubber, paper, paper-plastic composite, glass and metal packages, e.g. plastic bottles, pouches, coated paper cartons, vacuum bags, metal three-piece cans, plastic packages for cosmetics, soft tubes for tooth paste, jelly and yogurt cups.
Extended Applications
  • Closure Systems
    Water vapor barrier property of various closure systems for bottles, cartons and pouches.
  • Solar Back-sheets
    Water vapor permeability test of solar back-sheets
  • Plastic Tubes
    Water vapor permeability test of various sorts of tubes e.g. cosmetic tubes
  • Blister Packs
    Water vapor transmission rate of whole blister packs
  • Automotive and Small Engine Fuel Tanks
    Permeability of plastic fuel tanks
  • Battery Plastic Shell
    Water vapor transmission rate of battery plastic cell

Technical Specifications

Table 1: Test Parameters Note1

Parameter Model C330H
Test Range g/(m2·day) (Standard) 0.005 50
g/(100in2·day) 0.0003 3.223
g/(pkg·day)(Package) 0.000025 0.25
Resolution g/(m2·day) 0.001
Repeatability g/(m2·day) 0.005 or 2%
Test Temperature C 10 55 ±0.2
Test Humidity RH 5% 90% ±1%, 100%
Additional Functions Package Test (3L Max.) Optional
DataShieldTM Note2 Optional
Computer System required by GMP Optional
CFR21 Part11 Optional

Table 2: Technical Specifications

Test Chamber 3 test chambers
Specimen Size 108mm X 108mm
Specimen Thickness ‰3mm
Standard Test Area 50cm2
Carrier Gas 99.999% High-purity Nitrogen (outside of supply scope)
Carrier Gas Pressure ‰0.28MPa / 40.6psi
Port Size 1/8 inch metal tubing

Note 1: The parameters in the table are measured by professional operator in Labthink laboratory according to relative requirements for laboratory standard conditions.
Note 2: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be purchase as required.
Note 3: The described product features should be in line with Table 1: Test Parameters.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Water Vapor Transmission Rate Tester' category



Back to top
trade india member
LABTHINK INSTRUMENTS CO. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.