The preconditioned specimen is heated and evaporates in the beaker; the volatile constituents condense on the glass plate or aluminum foil treated in cooling chamber. Take off the glass plate or aluminum foil when the condensation process is finished. The fogging characteristics could be obtained by measuring condensed constituent weight and fogging value on the glass plate or aluminum foil and comparing with the data before condensation process.
This instrument conforms to the multiple international and national standards:
ISO 6452, DIN 75201, SAE J1756, QB/T 2728, BS EN 14288, PV 3920, PV 3015, ES-X83231, NES M0161, D45 1727, GM 9305P, TSM 0503G
Gloss Method: the specimen is heated in the beaker and its volatile constituents are condensed on the cooling glass plate. The fogging value could be obtained by calculating and comparing the gloss values occurred before and after condensation process.
Haze Method: the specimen is heated in the beaker and its volatile constituents are condensed on the cooling glass plate. The fogging value of the specimen could be obtained by calculating and comparing the fogging values occurred before and after condensation process.
Weighing Method: the specimen is heated in the beaker and its volatile constituents are condensed on the cooling aluminum foil. The fogging value - the weight of condensed constituents could be obtained by analyzing the weight changes of aluminum foil occurred before and after condensation process.
The instrument mainly consists of constant high-temperature bath, constant low-temperature bath, cooling plate, beaker, glass plate, meter, sample cutter and other accessories, through which it can perform the processes of sampling, heating, condensation and test.
Prepare specimens-----switch on high and low temperature baths-----clean beakers and glass plates------place specimens----place glass plate or aluminum foil-----place cooling chamber-----perform test for a specified period of time----take off glass plate or aluminum foil and place certain time----measure the gloss value, fogging value of glass plate or weight value of aluminum foil------compare the data and obtain test results
FT-F1 fogging tester is applicable to the determination of:
Basic Applications |
---|
|
|
Extended Applications |
|
|
|
|
|
Specifications | FT-F1 Fogging Tester |
---|---|
Temperature Range of High-Temperature Bath | Room temperature 150C (room temperature 280C is optional) |
Accuracy | ±0.1C (150C) |
Temperature Range of Low-Temperature Bath | 0 100C |
Accuracy | ±0.1C |
Size of High-Temperature Bath | 670 mm (L) x 490 mm (W) x 540 mm (H) |
Size of Low-Temperature Bath | 400 mm (L) x 220 mm (W) x 520 mm (H) |
Net Weight of High-Temperature Bath | 32 kg (except the weight of heat conducting medium) |
Net Weight of Low-Temperature Bath | 15 kg (except the weight of heat conducting medium) |
Power Supply | 220VAC 50Hz / 120VAC 60Hz |