Infrared Moisture Sensor
Accurate Data
High Efficient Three-chamber
Intelligent Control
Safe and Reliable
Powerful Functions
The pre-treated sample is clamped between the test chambers, the nitrogen with stable relative humidity flows on one side of the film, and the dry nitrogen flows on the other side of the film; due to the existence of humidity difference, water vapor will diffuse from the high humidity side through the film to the low humidity side; on the low humidity side, the water vapor is carried to the infrared water sensor by the flowing dry nitrogen, and different water vapor is generated. The concentration produces different light signals, and the concentration value is obtained through analysis and calculation, and then the water vapor transmission rate of the sample is calculated.
ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015
Applications |
---|
|
|
Table 1: Test Parameters Note2
Parameters/Model | C303H | |
---|---|---|
Test Scope | g/(m2·day) (standard area 50cm2) | 0.005ï40 (standard) 0.005100ï¼optionalï¼ |
g/(m2·day) (MASK area 5cm2) | 0.05400 (optional) | |
g/(m2·day) (MASK area 1cm2) | 0.252000 (optional) | |
Resolution | g/(m2·day) | 0.0001 |
Repeatability | g/(m2·day) | 0.005 or2%, whichever is greater |
Temperature Range | | 15ï50 560 (customized) |
Temperature Fluctuation | | ±0.05 |
Humidity Range | %Rh (within standard temperature range) | 5ï901% |
Extended Functions | DataShieldTM Data Shield Note 3 | Optional |
GMP Computer System Requirements | Optional | |
CFR21Part11 | Optional |
Table 2: Technical Specifications
Test Chamber | 3 sets |
---|---|
Sample Size | 4.4 x 4.4ï¼11.2cm11.2cmï¼ |
Sample Thickness | 120 Milï¼3mmï¼ |
Standard Test Area | 50cm2 |
Carrier Gas Specification | 99.999% high purity nitrogen (gas source is prepared by the user) |
Air Source Pressure | 40.6 PSI / 280 kPa |
Interface Size | 1 / 8 "metal tube |
Dimensions | 23.6 H x 19.6 W x 27.5 D (60cm 50cm 70cm) |
Power Supply | 120VAC ± 10% 60Hz / 220VAC ± 10% 50Hz |
Net Weight | 220Lbsï¼100kgï¼ |
Table 3: Product Configuration
Standard Configuration | Mainframe, tablet computer, sampler, vacuum grease, polyurethane pipe with diameter of 6 mm |
---|---|
Options | Air compressor, CFR21Part11, GMP computer system requirements, DataShieldTM Data Shield Notes3 |
Note | The compressed air inlet of the machine is Î 6 mm polyurethane pipe (pressure 79.7 psi / 550 kPa); the air source is prepared by the user. |
Note 1: the product features are subject to the specific notes in the "Technical Parameters" table.
Note 2: the parameters in the table are measured by professional operators in Labthink laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield system provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase it separately according to the usage.