Coulometric Sensor
Accurate data
High Efficiency
Intelligent control
Safe and reliable
Space saving
Powerful functions
The pre-conditioned specimen is clamped in the test cell, oxygen or air flows on one side of the specimen while a stream of high purity nitrogen flows on the other side. Oxygen molecules permeate through the specimen into the nitrogen side and are carried to the coulometric sensor. The sensor analyzes the oxygen concentration and calculates the oxygen transmission rate and other factors.
ASTM D3985ãASTM F1307ãGB/T 19789ãGB/T 31354ãDIN 53380-3ãJIS K7126-2-BãYBB 00082003-2015
Applications |
---|
|
|
Table 1: Test Parameters Note2
Parameters/Model | C206H | |
---|---|---|
Test range | cc/(m2·day) (Standard area 50cm2) | 0.02ï200 |
cc/(m2·day) (Standard area 50cm2) | 0.02ï400000ï¼Customizeï¼ | |
cc/(m2·day) (MASK area 5cm2) | 0.2ï2000ï¼Optionalï¼ | |
cc/(m2·day) (MASK area 1cm2) | 1ï10000ï¼Optionalï¼ | |
Resolution | cc/(m2·day) | 0.0001 |
Repeatability | cc/(m2·day) | 0.02 or 1%ï¼take the greater |
Test Temperature | | 15ï50ï¼5ï60ï¼Optionalï¼ |
Temperature fluctuation | | ±0.15 |
Test Humidity | %RHï¼Within standard test temperature rangeï¼ | 0%ï¼5ï902% |
Additional Functions | GP-01 Gas Purifier | Optional |
DataShieldTM note3 | Optional | |
GMP Computer System requirement | Optional | |
CFR21Part11 | Optional |
Table 2: Technical Specifications
Test Cell | 6 Cells |
---|---|
Specimen Size | 4.4 x 4.4ï¼11.2cm11.2cmï¼ |
Specimen Thickness | 120 Milï¼3mmï¼ |
Standard test area | 50cm2 |
Gas supply | 99.999% Nitrogenã99.5% Oxygenï¼ Outside of supply scopeï¼ |
Gas Pressure | 40.6 PSI / 280 kPa |
Port Size | 1/8 Metal tube |
Instrument Dimension | 23.6 H x 19.2 W x 25.9 D (60cm 49cm 66cm) |
Power Supply | 120VAC±10% 60Hz / 220VAC±10% 50Hzï¼one of twoï¼ |
Net Weight | 220Lbsï¼100kgï¼ |
Table 3: Product Configuration
Standard Configuration | Instrument mainframe, tablet, sampler, vacuum grease, Î6 mm PU tubing |
---|---|
Optional Parts | GP-01 Gas Purifier, Air compressor, CFR21Part11, GMP Computer System requirement, DataShieldTM note3 |
Note | The gas supply port of the instrument is Î6 mm PU tubingï¼pressure79.7 PSI/ 550kPaï¼, customers need to prepare gas supply. |
Note 1: The described product functions are subject to the specification in "Technical Parameters"
Note 2: The parameters in the table are measured in Labthink laboratory by professional operators according to the requirements and conditions stapulated in laboratory environmental standards.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
LABTHINK INSTRUMENTS CO. LTD.