Coulometric Oxygen Sensor
Accurate Data
Effective Three-Cell
Intelligent Operation
Safe and Reliable
Powerful Functions
The sample is clamped between the test chambers, oxygen or air flows on one side of the film, and high-purity nitrogen flows on the other side of the film. Oxygen molecules diffuse through the film into the high-purity nitrogen in the other side. The flowing nitrogen is carried to the sensor. Through the analysis of the oxygen concentration measured by the sensor, the oxygen transmittance is calculated.
ASTM D3985, ASTM F1307, ASTM F1927(option), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
Applications |
---|
|
|
Table 1: Test Parameters Note2
Parameters/Model | C203H | |
---|---|---|
Test Scope | cc/(m2*day) (standard area 50cm2) | 0.01200 0.005200 (optional) |
cc/(m2*day) (standard area 50cm2) | 0.01400000ï¼Customizeï¼ | |
cc/(m2*day) (MASK area 5cm2) | 0.12000 (optional) | |
cc/(m2*day) (MASK area 1cm2) | 0.510000 (optional) | |
Resolving Power | cc/(m2*day) | 0.0001 |
Repeatability | cc/(m2*day) | 0.01 or1%, whichever is greater |
Temperature Range | C | 1550 560 (customized) |
Temperature Fluctuation | C | +-0.05 |
Humidity Range | %Rh (within standard temperature range) | O2: 0%ï¼5901% Carrier Gas: 0%, 5902% |
Extended Functions | GP-01 Gas Purification Unit | Optional |
DataShieldTM Data Shield Note 3 | Optional | |
GMP Computer System Requirements | Optional | |
CFR21Part11 | Optional |
Table 2: Technical Specifications
Test Chamber | 3 sets |
---|---|
Sample Size | 4.4'' x 4.4''ï¼11.2cmx11.2cmï¼ |
Sample Thickness | <=120 Milï¼3mmï¼ |
Standard Test Area | 50cm2 |
Gas Specification | 99.999% nitrogen, 99.5% oxygen (gas source prepared by the buyer) |
Air Source Pressure | >= 40.6 PSI / 280 kPa |
Interface Size | 1 / 8 "metal tube |
Dimensions | 23.6'' H x 19.6'' W x 27.5'' D (60cmx 50cmx 70cm) |
Power Supply | 120VAC +-10% 60Hz / 220VAC +-10% 50Hz (choose one from those two) |
Instrument Dimension | 23.6'' H x 19.2'' W x 25.9'' D (60cmx 49cmx 66cm) |
Net weight | 220Lbs(100kg) |
Table 3: Product Configuration
Standard Configuration | Mainframe, tablet computer, sampler, vacuum grease, polyurethane pipe with diameter of 6 mm |
---|---|
Options | Gp-01 Gas Purification Unit, air compressor, CFR21Part11, GMP computer system requirements DataShieldTM Data ShieldNote3 |
Remarks | The compressed air inlet of the machine is 6 mm polyurethane pipe (pressure >= 79.7 psi / 550 kPa); the air source is prepared by the buyer. |
Note 1: All the product features are subject to detailed descriptions in the "Technical Parametersï.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase respectively according to the usage.