Accurate Data
High Efficiency
Intelligent control
Safe and reliable
Space saving
Powerful functions
The pre-conditioned specimen is mounted in the test cell as to form a sealed barrier between two chambers. The lower-pressure chamber (lower chamber) is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber (upper chamber) and a constant pressure (adjustable) difference is generated between the two chambers. The gas permeates through the specimen from higher pressure side into the lower pressure side. The gas permeability and other barrier properties of the specimen can be obtained by analyzing the pressure changes in the lower chamber.
ISO 15105-1, ISO 2556, GB/T 1038-2000, ASTM D1434, JIS K7126-1 ,YBB 00082003
Applications |
---|
|
|
Table 1: Test Parameters Note2
Parameters/Model | C106H | |
---|---|---|
Test range | cm3/m2*24h*0.1MPa | 0.01-50,000 |
Resolution | cm3/m2*24h*0.1MPa | 0.001 |
Test temperature | |
15-50ï¼5-60ï¼Optionalï¼ |
Temperature resolution | |
0.01 |
Temperature fluctuation | |
±0.15 |
Test humidity | %RHï¼Within standard test temperature rangeï¼ | 0%ï¼5-90±2%ï¼Customizeï¼ |
Vacuum Resolution | Pa | 0.01 |
Vacuum Accuracy | Pa | ±0.2%ï¼1%-100% of Full Scaleï¼ |
Vacuum Degree of Test Chamber | Pa | 10 |
Additional Functions | DataShieldTM note3 | Optional |
GMP Computer System requirement | Optional | |
CFR21Part11 | Optional |
Table 2: Technical Specifications
Test Cell | 6 Cells |
---|---|
Specimen Size | 4.6'' x 4.6''ï¼11.7cmx11.7cmï¼ |
Specimen Thickness | 120 Milï¼3mmï¼ |
Standard test area | 38.48cm2 |
Test Gas | O2, N2, CO2 etc.ï¼Outside of supply scopeï¼ |
Test Pressure | 10 kPa210 kPaï¼Can be set betweenï¼ |
Pressure Fluctuation | 0.2 kPa |
Gas Pressure | 79.7 PSI / 550 kPa |
Port Size | 6 mm PU tubing |
Instrument Dimension | 23.6'' H x 19.2'' W x 25.9'' D (60cmx 49cmx 66cm) |
Power Supply | 120VAC 10% 60Hz/220VAC±10% 50Hzï¼one of twoï¼ |
Net Weight | 220Lbsï¼100kgï¼ |
Table 3: Product Configuratio
Standard Configuration | Instrument mainframe, tablet, vacuum pump (UK), sampler, vacuum grease, 6 mm PU tubing |
---|---|
Optional Parts | Air compressor, CFR21Part11, GMP Computer System requirement, DataShieldTM note3 |
Note | The gas compressor port of the instrument is 6 mm PU tubingï¼pressure79.7 PSI/ 550kPaï¼, customers need to prepare gas supply. |
Note 1: The described product functions are subject to the specification in "Technical Parameters" "Table 1: Test Parameters".
Note 2: The parameters in the table are measured in Labthink laboratory by professional operators according to the requirements and conditions stapulated in laboratory environmental standards.
Note 3: DataShieldTM provides safe and reliable data application support. Multiple Labthink instruments can share one single DataShieldTM system which can be configured as required.
LABTHINK INSTRUMENTS CO. LTD.
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |